The Slot Monitor (Slotmon) application monitors the status of all slots and system cards installed in a slot on a Sonus Signaling System. Specifically, Slotmon monitors:

  • the physical status of a card
  • the status of the IP address or addresses of a card
  • the status of individual applications on a card if any exist

When Slotmon detects a status change, a corresponding event or alarm may be triggered and recorded in ptisyslog, sent as an SNMP trap, or displayed in the Alarm Dashboard of the Web UI (see event numbers 6240 to 6279 in Alarm Definitions for a list of Slotmon related events). These events display a severity level, and indicate the card’s physical status, IP address status, or application status.

Slotmon information can be accessed using the Slot Monitor Details screen (see the following figure). 

Figure : Slot Monitor Details Screen

  

The following table lists and describes the attributes on the Slot Monitor Details screen.

Table : Slot Monitor Details Screen Attribute Listing and Description

Attribute Description
Chassis Type Read-only attribute that indicates the chassis type.
Hostname Read-only attribute that indicates the hostname of the active Management CPU running the Slotmon process.
Debug Logging

Read-only attribute that indicates the Slotmon debug level.

   
The following figure is an example of the Slot Details screen.

Figure : Slot Details Screen

  

The following table lists and describes the attributes on the Slot Details screen.

Table : Slot Details Screen Attribute Listing and Description

Attribute Description
Slot Number Read-only attribute that indicates the physical slot location in the chassis.
Slot Type Read-only attribute that indicates the card type in a slot.
Slot Status

Read-only attribute that indicates the status of the slot determined by the Slotmon application.

Values are:

  • EXTRACTED: the card in a slot has been properly extracted.
  • AVAILABLE: a slot is communicating normally with the slotmon.
  • UNKNOWN_STATE: a slot is not present.
  • PENDING_EXTRACTION_REQUEST: slotmon has sent an extraction request to this slot.
  • READY_TO_BE_EXTRACTED: slot is ready for card extraction.
  • LOST_CONNECTION: slotmon has lost connection to this slot.
Primary IP Read-only attribute that indicates the primary IP address for the slot.
Secondary IP Read-only attribute that indicates the secondary IP address for the slot.
Primary IP State

Read-only attribute that indicates the state of the primary IP address for a slot.

Values are:

  • IP_UNKNOWN
  • IP_UP
  • IP_DOWN
  • IP_PENDING_DOWN
Secondary IP State

Read-only attribute that indicates the state of the secondary IP address for a slot.

Values are:

  • IP_UNKNOWN
  • IP_UP
  • IP_DOWN
  • IP_PENDING_DOWN
Monitor State

Read-only attribute that indicates the Slotmon monitor state for a slot. Slotmon starts monitoring a slot when the slot in populated with a card and is commissioned during the card installation process.

Values are:

  • ENABLED
  • DISABLED


The following figure is an example of the Application Details screen.

Figure : Application Details Screen

  

The following table lists and describes the attributes on the Application Details screen.

Table : Application Details Screen Attribute Listing and Description

Attribute Description
Slot Number Read-only attribute that indicates the physical slot location in the chassis.
Application Name

Read-only attribute that indicates the application name.

Application State

Read-only attribute that indicates the status of the application determined by Slotmon.

Values are:

  • RUNNING
  • STOPPED

To view application details

  1. From the Main Menu, click Slot Monitor.

  2. Select the required slot number.

  3. Select the application for which you want to view detailed information.

      

  • No labels