monitor

Purpose

Control presentation of alarm notifications for a specified facility to the current CLI session.

Command Mode


Required Access

level 0

Description

For all named alarm types, you can either enable or disable alarm output.

Syntax

monitor alarm <parameters>

Parameters and Operations

Description

none

Disable all alarm output, regardless of severity.

all

Enable all alarm output, regardless of severity.

bcmp

Control BCMP alarm output.

bdap

Control BDAP alarm output.

bmp

Control BMP alarm output.

bsp

Control BSP alarm output.

cas

Control CAS channel alarm output.

cfg

Control configuration alarm output.

cli

Control CLI alarm output.

h323

Control H323 alarm output.

ibp

Control IBP alarm output.

ip

Control IP alarm output.

isdn

Control ISN channel alarm output.

isup

Control ISUP channel alarm output.

ivr

Control IVR script alarm output.

proc

Control script interpreter alarm output.

rtp

Control RTP alarm output.

sig

Control signaling alarm output.

sip

Control SIP alarm output.

snmp

Control SNMP alarm output.

sys

Control VX kernel alarm output.

tel

Control telephony alarm output.

vox

Control alarm output from voice resources

vtp

Control VTP alarm output.