Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 

 

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to Customer Replaceable Units

Back to SBC 7000 Series CRUs

...

To replace a CSC, do the following:

  1. Backup the configuration. Before installing a new license file, a configuration backup must be taken by using the command saveConfig, which generates the .tar.gz backup file prior to the replacement. he backup must be taken before performing any operation on the system. For detailed information, refer to Restoring SBC Configuration.
  2. Perform a graceful shutdown of the 
    Spacevars
    0series2
    system through BMC GUI.
  3. Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis (see Connecting Electrostatic Discharge Wrist Strap on SBC 7000 for details).
  4. Remove all the existing connections from all the ports.
  5. Unscrew the thumb screws using #2 Phillips-head screwdriver, open release levers on each side, and pull the CSC module out.

    Caption
    0Figure
    1SBC 7000 Core Server Card pulled out

  6. To replace, insert the new module to the correct slot, push the CSC module completely.
  7. Close the release levers.
  8. Tighten the thumb screws using #2 Phillips-head screwdriver.
  9. Re-connect all the ports.
  10. Start the
    Spacevars
    0series2
    system through BMC GUI.

...