ASM Behavior on Sonus SBC 1000/2000 Reboot Operation

Unable to show "metadata-from": No such page "_space_variables"
(SBC) model, users with a built-in Working with the ASM: SBA, CCE and 3rd Party Applications may be impacted by this operation:

  • Sonus SBC 2000
  • If the ASM is running, rebooting the SBC will cause the ASM to also reboot.
  • If the ASM is shut down, rebooting the SBC will not restart the ASM.
  • To bring the ASM back into operation, you must physically power off and power back on the SBC.
  • Sonus SBC 1000 --- rebooting the SBC will not have an effect on the ASM.

Rebooting the Sonus SBC Edge

To reboot the Sonus SBC Edge system:

  1. In the WebUI, click the Tasks tab.
  2. In the left navigation pane, under the System, click Reboot Sonus SBC.

    Figure : Reboot

  3. Click OK.The following popup will be displayed to confirm the action:

    Figure : Confirm

  4. Click OK to reboot the Sonus SBC Edge
  5. The web interface will dispatch the following status message throughout the reboot cycle.

    Figure : Status Message

On average, the Sonus SBC 1000/2000 system takes between 3 to 4 minutes to fully reboot and become reachable again through the web interface.

Upon completion, you will be automatically redirected to the  Login Screen